[Exigences d'évaluation du CCMC] ANSI/APA PRR 410-2021, catégorie C2
De : Conseil national de recherches Canada
Document énonçant les critères d'évaluation
Numéro | ANSI/APA PRR 410-2021, catégorie C2 |
Titre | |
Document | Norme |
Éditeur | American National Standards Institute |
Portée
These evaluations are in accordance with ANSI/APA PRR 410-21, “Standard for Performance-Rated Engineered Wood Rim Boards.” The standard applies to products manufactured from either structural-use panels sawn into rim board dimensions, re-sawn structural glued laminated timber, or structural composite lumber manufactured specifically to meet the performance requirements of rim boards in wood-frame construction.
Grade C2 rim boards meeting the requirements in ANSI/APA PRR 410 have a thickness-based rim board grade of 25.4 mm (1 in.) thick or higher.
The maximum depth of these rim boards is 610 mm (24 in.).
In accordance with structural performance criteria, “APA Rim Board” is equivalent to Grade C2 rim boards as listed in Table 2.
The rim boards are intended for use in engineered wood joist floor assemblies in dry service conditions only (i.e., conditions where the mean equilibrium moisture content of solid sawn lumber is less than 16%). The rim boards are manufactured to meet the standard and are subject to a third-party certification program accredited by the Standards Council of Canada.
Exigences matérielles
Le titulaire de l'évaluation doit démontrer que le produit satisfait aux exigences suivantes (au besoin, des exigences supplémentaires pourraient être imposées par le CCMC, et ces dernières sont détaillées dans l'évaluation en question) :
The standard prescriptive and performance requirements are summarized below. This standard addresses the following aspects: The horizontal load transfer capacity, uniform vertical load capacity, 12.7-mm-diameter (1/2 in.) lag screw lateral resistance, and concentrated vertical load capacity must meet the required mean test values specified in ANSI/APA PRR 410. The design values outlined in Table 2 apply only to engineered wood rim boards meeting the minimum structural performance specified in ANSI/APA PRR 410. Table 2 outlines the design values for engineered buildings. These factored resistance values for limit states design are soft-converted from the allowable working stress design values. To determine the factored resistances, tests are carried out in accordance with the standard, which also specifies sample preparation. All the samples are assembled and nailed in accordance with the nailing schedule shown in Table 3, which complies with the NBC 2015 requirements. (N/mm) (N/mm) (kN) (kN) The nailing schedule in Table 3 was used to prepare the samples to test for the structural performance criteria. It is also the nailing schedule required by the NBC 2015 and should be followed during field installation. Figure 1 graphically displays the nailing requirements. Figure 1. Typical installation for performance-rated engineered wood rim board The mean edge nailing durability of the conditioned samples must be at least 75% of the mean horizontal load transfer capacity of the unconditioned samples. After conditioning, the mean thickness swell must not exceed 10% and the thickness swell of individual samples must not exceed 12%. The density values and internal bond measurements are used to establish quality control values for the quality assurance use. A 15 ng/(Pa∙s∙m2) vapour barrier must be installed on the interior side to address the requirements of Article 9.25.4.2., Vapour barrier materials, and subsection 9.25.5., properties and position of materials in the building envelope, of Division B of the NBC 2020. Engineering support for performance-rated engineered wood rim boards is provided by either the third-party certification agency or by the manufacturer. Check the product listing for engineering support contact information.
Dimensions and dimensional tolerances
Performance category
Thickness (mm (in.))
Maximum depth (mm (in.))
Depth toleranceTable footnote (1)Table footnote (2) (mm (in.))
Minimum thicknessTable footnote (3) (mm (in.))
Maximum thickness (mm (in.))
25.4 (1)
25.4 (1)
610 (24)
+3.2 (+1.8)
–0 (–0)24.13 (0.950)
26.67 (1.050)
Structural performance
Performance category
Depth limitationsTable footnote (3) (mm)
d ≤ 610
241.3
301.6
355.6
406.4
457.2
508
558.8
609.6
d ≤ 610
d ≤ 610
25.4 mm or higher
3.20
91.03
91.03
82.56
69.86
58.22
48.69
41.29
34.94
2.22
22.57
Sheathing to rim board or joistTable footnote (2)
Bottom plate through sheathing to rim board
Rim board to sill plates (toe nail)
Joist to sill plate (slanted)
Rim board to joist
51 mm (6d) common @ 150 mm o.c. (6 in. o.c.)Table footnote (3) or 63.5 mm (8d) common @ 150 mm o.c. (6 in o.c.)Table footnote (4)
82 mm (12d) common @ 400 mm (15.7 in. o.c.) or 82 mm (12d) common @ 150 mm (6 in. o.c.)Table footnote (5)
82 mm (12d) common @ 150 mm (6 in. o.c.)
2 × 63.5 mm (8d) common
2 × 63.5 mm (8d) common
Edge nailing durability criteria
Physical properties (not applicable to plywood panels, laminated veneer lumber or glulam material)
Vapour barrier
Engineering support
© American National Standards Institute. This information is reproduced from the referenced standard published by the American National Standards Institute (ANSI). The full version of the Standard should be referenced, and can be obtained from ANSI.
Exigences relatives à l'installation
Le CCMC exige que les titulaires d'évaluation fournissent des instructions d'installation de produits qui :
- ne vont pas à l'encontre du Code national du bâtiment – Canada ou de tout autre code du bâtiment provincial ou territorial; et
- satisfont aux exigences minimales en matière de documentation du CCMC.
Exigences relatives à la fabrication
Le CCMC exige que les titulaires d'évaluation puissent, à tout le moins, démontrer que le processus de production associé :
- s'effectue selon un système qualité documenté; et
- satisfait aux exigences minimales en matière de documentation du CCMC.
Exigences relatives à l'étiquetage
Le CCMC exige des titulaires d'évaluation qu'ils s'assurent que les étiquettes des produits :
- renvoient au numéro ou à la marque du CCMC qui y sont associés; et
- satisfont aux exigences minimales en matière de documentation du CCMC.
All performance-rated engineered wood rim boards must be labelled with the following information:
Renseignements sur la classification
Les produits qui relèvent de ce document sont généralement classés dans :
Répertoire normatif (MasterFormatᴹᴰ)
- 06 10 00 Rough Carpentry
- 06 17 00 Shop-Fabricated Structural Wood
- 06 17 43 Rim Boards
Évaluations du CCMC publiées
Les produits suivants ont été évalués par le CCMC en fonction de ces exigences :
Numéro du CCMC : | Fabricant : | Noms des produits : |
---|---|---|
13248-L | APA – The Engineered Wood Association | West Fraser Rimboard Grade B2, West Fraser Rimboard Grade C1, West Fraser Rimboard Grade C2, West Fraser Rimboard Grade A, West Fraser Rimboard Grade B1 |