[CCMC evaluation requirements] CAN/ULC-S716.1-12
From: National Research Council Canada
This document provides a summary of the minimum requirements imposed by the Canadian Construction Materials Centre (CCMC) for all evaluations based on the below criteria document. Additional requirements may be imposed by the CCMC when necessary for a particular evaluation, and are detailed in the individual evaluation.
Criteria document
Number | CAN/ULC-S716.1-12 |
Title | Exterior Insulation and Finish Systems (EIFS) – Materials and Systems |
Document | Standard |
Publisher | ULC Standards |
Scope
This Standard outlines requirements for Exterior Insulation and Finish Systems (EIFS), used in combination with a drained air space as an exterior wall cladding system. It also outlines requirements for water resistive barrier systems (WRBs) that can be used with EIFS.
The EIFS wall cladding system is comprised of thermal insulation boards, an adhesive for attachment of the thermal insulation boards to the substrate, a glass fibre reinforcing mesh embedded in a base coat on the face of the thermal insulation boards and a finish coat.
The use of mechanical fasteners is outside the scope of this Standard, but is acceptable as a complement and/or as an alternate to adhesive for attachment where the substrate will not support adhesive attachment of the EIFS.
Note: Refer to CAN/ULC-S716.3, Annex A for further information.
In EIFS, the thermal insulation boards support the base coat with integral glass fibre reinforcing mesh. Systems where the reinforcement is the supporting element of the rendering, e.g., conventional stucco, are not covered by this Standard.
This document does not purport to address all the health and safety aspects associated with its use. Anyone using this Standard has the responsibility to consult the appropriate authorities and to establish health and safety practices, in conjunction with any existing applicable regulatory requirements, prior to its use.
Material requirements
The evaluation holder must demonstrate that the product meets the following requirements (additional requirements may be imposed by the CCMC when necessary, and are detailed in the individual evaluation):
Test | Requirement | Notes |
---|---|---|
Bond strength of adhesives to LA-WRB | avg. ≥ 80 kPa | Wet State |
avg. ≥ 250 kPa | Initial and dry state | |
Bond strength of adhesive to concrete block | avg. ≥ 80 kPa | Wet state |
avg. ≥ 250 kPa | Initial and dry state | |
Bond strength of base coat to thermal insulation board | avg. ≥ 80 kPa | All states |
Bond strength of finish coat to base coat | avg. ≥ 80 kPa | All states |
Water vapour permeance of the lamina | There is no pass/fail criterion for the water vapour permeance of the lamina. | Water vapour permeance of the lamina is included for potential hygrothermal design purposes. |
Water impermeability of base coat | < 90 % of surface area damp | |
Water absorption of base coat | < 20 % avg. mass gain | |
Fungus resistance of finish coat | No fungal growth supported | |
Salt spray resistance of lamina | No deleterious effects visible | |
Ultra violet resistance of lamina | No deleterious effects visible | |
Strength of reinforcing mesh | Avg. initial strength ≥ 35 N/mm | For both weft and warp |
Strength of reinforcing mesh after tri-alkai solution exposure | Avg. Residual strength ≥ 20 N/mm and a loss in ultimate tensile strength of not more than 50 % | For both weft and warp |
Strength of reinforcing mesh after cement solution exposure | Avg. Residual strength ≥ 15 N/mm and a loss in ultimate tensile strength of not more than 60 % | For both weft and warp |
Dry thickness of the base coat | There is no pass/fail criterion for the dry thickness of the base coat test. | Dry thickness of the base coat is determined for verification purposes only. |
© Underwriters Laboratories of Canada Inc. Reprinted with permission. This material is not the complete and official position of ULC Standards on the referenced subject, which is represented only by the ULC Standard in its entirety.
Installation requirements
The CCMC requires that evaluation holders provide instructions for the installation of the product(s) that:
- do not contravene the National Building Code of Canada, or any provincial or territorial building codes; and
- meet the requirements of CCMC minimum documentation requirements.
Manufacturing requirements
The CCMC requires that evaluation holders, at a minimum, demonstrate that the associated production process:
- is operated under a documented quality system; and
- meets the minimum requirements of the CCMC minimum documentation requirements.
Labelling requirements
The CCMC requires that evaluation holders ensure that product labels:
- reference the associated CCMC number or mark; and
- meet the requirements of CCMC minimum documentation requirements.
Additionally, in compliance with CAN/ULC-S716.1, each container/package shall be marked with the following information, unless otherwise specified:
- Manufacturer’s name and address;
- Product name;
- Product description;
- The statement, “Complies with CAN/ULC-S716.1”;
- Manufacturer’s lot or date code identification of the material in the container.
Classification information
Products falling within the scope of this document are commonly classified by:
MasterFormat®
- 07 24 00 Exterior Insulation and Finish Systems
- 07 24 13 Polymer-Based Exterior Insulation and Finish System
- 07 24 16 Polymer-Modified Exterior Insulation and Finish System
- 07 24 19 Water-Drainage Exterior Insulation and Finish System
- 07 24 23 Direct-Applied Finish Systems
Published CCMC evaluations
The following products have been evaluated to these requirements by the CCMC:
CCMC number: | Manufacturer: | Product names: |
---|---|---|
12416-R | Sto Canada Ltd. | StoTherm®ci Classic, StoTherm®ci Essence, StoTherm®ci Lotusan |
12913-R | Les Systèmes Adex Inc. | Adex-VCA, Adex-MFS, Adex-RS |
13062-R | MBSCS Canada, Inc | Senerflex Wall System |
13232-R | Les Enduits STEF Inc. | Stef Premium II, Stef Green Plus, Stef Premium Drainscreen, Stef Green, Stef Impermea |
14298-R | Parex USA, Inc. | Parex Standard WaterMaster CI |
Code references
National Building Code of Canada 2015
Code references | Code provision |
---|---|
5.9.4.1.(1) | Exterior insulation finish systems and t ... |
9.27.13.2.(1) | The materials used in EIFS shall conform ... |
National Building Code of Canada 2020
Code references | Code provision |
---|---|
5.9.4.1.(1) | Exterior insulation finish systems and t ... |
9.27.14.2.(1) | The materials used in EIFS shall conform ... |