[CCMC evaluation requirements] CAN/ULC-S705.1-15
From: National Research Council Canada
This document provides a summary of the minimum requirements imposed by the Canadian Construction Materials Centre (CCMC) for all evaluations based on the below criteria document. Additional requirements may be imposed by the CCMC when necessary for a particular evaluation, and are detailed in the individual evaluation.
Criteria document
Number | CAN/ULC-S705.1-15 |
Title | Standard for Thermal Insulation - Spray Applied Rigid Polyurethane Foam, Medium Density - Material Specification |
Document | Standard |
Publisher | ULC Standards |
Scope
These evaluations apply to spray-applied, rigid polyurethane foam of medium density intended for use as thermal insulation for both building and non-building applications, whether applied on a building site or in a prefabrication (manufacturing) process. This material is also known as foamed in-situ insulation. The continuous-use temperature is within the range of –60°C to +80°C.
For compliance to CAN/ULC-S705.2, users should contact the third-party organization that has been identified by the foam manufacturer as the third party operating the site quality assurance program (SQAP) for the foam product (see product Listing).
Material requirements
The evaluation holder must demonstrate that the product meets the following requirements (additional requirements may be imposed by the CCMC when necessary, and are detailed in the individual evaluation):
Property | Unit | Miminum requirement for CAN/ULC-S705.1-15 | Maximum requirement for CAN/ULC-S705.1-15 | |
---|---|---|---|---|
Air permeance (mandatory material testing) | L/s @ 75 Pa | No min. | 0.02 | |
Air permeance (optional system testing) | L/s @ 75 Pa | – | – | |
Apparent core density | kg/m3 | 28 | No max. | |
Compressive strength | kPa | 170 | No max. | |
Dimensional stability volume change at –20°C | % | –2 | 5 | |
Dimensional stability volume change at 80°C | % | –2 | 8 | |
Dimensional stability volume change at 70°C, 97 ± 3% RH | % | –2 | 14 | |
Surface burning characteristics – flame spread rating | – | No min. | 500 Footnote (1) | |
Fungi resistance | – | No growth | – | |
Open-cell content volume | % | No min. | 10 | |
Long-term thermal resistance (LTTR) Footnote (2) of a 50-mm-thick specimen at 25 mm thick | m2·°C/W | Declare | No max. | |
Long-term thermal resistance (LTTR) Footnote (2) of a 50-mm-thick specimen at 50 mm thick | m2·°C/W | 1.80 | No max. | |
Long-term thermal resistance (LTTR) Footnote (2) of a 50-mm-thick specimen at 75 mm thick | m2·°C/W | Declare | No max. | |
Tensile strength | kPa | 200 | No max. | |
Volatile organic emissions (time-to-occupancy) | d - days | No min. | 30 | |
Water absorption by volume | % | No min. | 4 | |
Water vapour permeance of a 50-mm-thick specimen | ng/(Pa·s·m2) | No min. | 60 |
© Underwriters Laboratories of Canada Inc. Reprinted with permission. This material is not the complete and official position of ULC Standards on the referenced subject, which is represented only by the ULC Standard in its entirety.
Installation requirements
The CCMC requires that evaluation holders provide instructions for the installation of the product(s) that:
- do not contravene the National Building Code of Canada, or any provincial or territorial building codes; and
- meet the requirements of CCMC minimum documentation requirements.
Manufacturing requirements
The CCMC requires that evaluation holders, at a minimum, demonstrate that the associated production process:
- is operated under a documented quality system; and
- meets the minimum requirements of the CCMC minimum documentation requirements.
Labelling requirements
The CCMC requires that evaluation holders ensure that product labels:
- reference the associated CCMC number or mark; and
- meet the requirements of CCMC minimum documentation requirements.
Additionally, in compliance with CAN/ULC-S705.1-15, each liquid component container must be identified as either the polymeric isocyanate component (“A”) or the resin component (“B”). The polymeric isocyanate component must be marked with the following information:
- supplier’s name;
- material name;
- type of material (e.g., closed cell spray applied medium density);
- net mass of the contents of the containers;
- country of manufacturer; and
- lot number.
The resin component must be marked with the following information:
- supplier’s name;
- material name;
- type of material (e.g., closed cell spray applied medium density);
- net mass of the contents of the containers;
- manufacturing location;
- lot number;
- date of manufacture;
- expiry date;
- means to identify the installed material;
- CAN/ULC-S705.1;
- LTTR (50 mm) RSI X.XX; and
- The statement “required to be installed according to CAN/ULC-S705.2.”
Classification information
Products falling within the scope of this document are commonly classified by:
MasterFormat®
- 07 21 00 Thermal Insulation
- 07 21 19 Foamed-In-Place Insulation
- 07 21 19.02 Thermal Insulation - Site Manufactured - Spray-Applied Polyurethane Foam
Published CCMC evaluations
The following products have been evaluated to these requirements by the CCMC:
CCMC number: | Manufacturer: | Product names: |
---|---|---|
13697-L | Elastochem Specialty Chemicals Inc. | Insulthane® Extreme ccSPF |
14078-L | Huntsman Building Solutions (Canada) Inc. | Heatlok® SOYA HFO, Polar Foam SOYA HFO, Airmetic® SOYA HFO |
14087-L | SES Foam LLC | Nexseal™ 2.0 CDN |
14100-L | BASF Canada Inc. | WALLTITE® CM01 |
14141-L | Soprema Inc. | SOPRA-SPF 202, SOPRA-SPF 202 LT |
14133-L | Canadian Urethane Spray Equipment (CUSE) | Grizzly Gold |
14140-L | SOLUTIONS Genyk Inc. | BOREAL NATURE elite |
14163-L | SHUNDA Polyurethane Ltd. | Kawartha 2000 |
14178-L | Johns Manville | JM Corbond IV® Canada |
14373-L | Gaco, a Division of Firestone Building Products Company, LLC | GacoOnePass Low GWP F1880 |
14414-L | Soprema Inc. | SOPRA-SPF 200 |
Code references
National Building Code of Canada 2015
Code references | Code provision |
---|---|
9.25.2.2. | Insulation Materials |
A-9.36.2.4.(1) | Calculating the Effective Thermal Resistance of Building Envelope Assemblies |
Table 5.9.1.1. | Standards Applicable to Environmental Separators and Assemblies Exposed to the Exterior |