[CCMC evaluation requirements] CAN/ULC-S701-11, Type 3

From: National Research Council Canada

This document provides a summary of the minimum requirements imposed by the Canadian Construction Materials Centre (CCMC) for all evaluations based on the below criteria document. Additional requirements may be imposed by the CCMC when necessary for a particular evaluation, and are detailed in the individual evaluation.

Criteria document

Scope

These evaluations apply to factory-made, rigid expanded polystyrene insulation in the form of pipe covering and boards with or without facings or coatings and made by moulding (EPS) or extrusion (XPS) of expandable polystyrene beads. It is intended for use as a thermal insulation in building construction and other applications within a temperature range of −54°C to +75°C.

Products covered by one of the standards listed below are also used for sound insulation and in prefabricated thermal insulation systems and composite panels. The performance of systems incorporating these products is not covered by the evaluation.

The following assessment criteria is for Type 3 products

       Notes:

  • The expanded polystyrene (EPS) insulation industry subscribes to an accredited certification program as part of their quality assurance. Some listings for EPS insulation products that are published in the Canadian Construction Materials Centre (CCMC) Registry are based on the participation of one of the certification organizations accredited by the Standards Council of Canada (SCC).
  • Annex A of CAN/ULC-S701-11 includes requirements for flat, uncoated EPS thermal insulation boards that are to be used in exterior insulation and finish systems (EIFS). Annex A forms a mandatory part of the standard.

Material requirements

The evaluation holder must demonstrate that the product meets the following requirements (additional requirements may be imposed by the CCMC when necessary, and are detailed in the individual evaluation):

Table 1. CAN/ULC-S701-11 Type 3 material properties
Property Unit Requirement
Thermal resistance of a 25-mm-thick specimen m2·°C/W ≥ 0.74
Long-term thermal resistance (LTTR)Footnote (1) m2·°C/W ≥ 1.68
Water vapour permeance for a 25-mm-thick specimen ng/(Pa·s·m2) ≤ 130
Dimensional stability % linear change ≤ 1.5
Flexural strength kPa ≥ 300
Water absorption % by volume ≤ 2.0
Compressive strength kPa ≥ 140
Limiting oxygen index % ≥ 24


© Underwriters Laboratories of Canada Inc. Reprinted with permission. This material is not the complete and official position of ULC Standards on the referenced subject, which is represented only by the ULC Standard in its entirety.

Installation requirements

The CCMC requires that evaluation holders provide instructions for the installation of the product(s) that:

Additionally, where EPS insulation is to be used in EIFS applications, users must refer to the Annex mentioned in the standard for mandatory additional requirements.

Manufacturing requirements

The CCMC requires that evaluation holders, at a minimum, demonstrate that the associated production process:

Additionally, the expanded polystyrene (EPS) insulation industry subscribes to an accredited certification program as part of their quality assurance. Some assessments for EPS insulation products that are published in the Canadian Construction Materials Centre (CCMC) Registry are based on certification by an accredited product certification body.

Labelling requirements

The CCMC requires that evaluation holders ensure that product labels:

Additionally, the product must be marked with the following information:

  • type;
  • ULC standard number;
  • product thickness;
  • thermal resistance per unit of thickness (LTTR for XPS); 
  • product identification number; and
  • manufacturer's name or trademark.

The product must also be marked with the warning:

"Caution: This product is combustible. A protective barrier or thermal barrier is required as specified in the appropriate building code."

Classification information

Products falling within the scope of this document are commonly classified by:

MasterFormat®

  • 07 21 00 Thermal Insulation
  • 07 21 13 Board Insulation
  • 07 21 13.13 Foam Board Insulation

Published CCMC evaluations

The following products have been evaluated to these requirements by the CCMC:

CCMC number:Manufacturer:Product names:
12426-LPlasti-Fab Ltd. PlastiSpan 25 Type 3, PlastiSpan M28, DuroFoam 25, PlastiSpan M-30, PlastiSpan M-40, PlastiSpan 40, PlastiSpan 25
13177-LDowneast Plastics Ltd. Thermalite Type 3
13524-LAmvic Inc. Silver Board
13526-LLe Groupe Legerlite Inc. Legerlite Type III
13638-LIsolofoam Group Inc. iFLEXFOAM 200, ISOLOFOAM HD30, iFLEXFOAM 300, ISOLOFOAM XHD 300, ISORAD V2 300, ISOLOFOAM HD40, ISOLOFOAM XHD 400, ISORAD V2 250, ISORAD V2 300 R3-R5, ISOLOFOAM 250, ISOLOFOAM XHD 250, ISOLOFOAM XHD 600, ISOLOFOAM Type 3
14004-LLogix BrandsHalo
14007-LLogix BrandsHeat-Sheet
14033-LAMC Foam Technologies Inc.Styrobar® 28
14034-LAMC Foam Technologies Inc.Styrobar® HS-40
14062-LHW Manufacturing Inc. Thermal 3Ht, Quik-Therm™, Comfort-R
14097-LSuperform Products Ltd. Superform Expanded Polystyrene Thermal Insulation
14014-LPowerWool Insulation Inc.Vertibreak Insulation

Code references

This standard is not referenced in the National Building Code of Canada