Search

[CCMC evaluation requirements] CAN/ULC-S701-05, Type 3

From: National Research Council Canada

This document provides a summary of the minimum requirements imposed by the Canadian Construction Materials Centre (CCMC) for all evaluations based on the below criteria document. Additional requirements may be imposed by the CCMC when necessary for a particular evaluation, and are detailed in the individual evaluation.

Criteria document

Scope

These evaluations are of factory made rigid expanded polystyrene insulation in the form of pipe covering and boards with or without facings or coatings made by moulding (EPS) or extrusion (XPS) of expandable polystyrene beads. They include products intended for use as thermal insulation in building construction and other applications for temperatures ranging from -54°C to + 75°C. They do not include laminated products manufactured with any type of rigid board facer including fibreboard, perlite board, gypsum board or oriented strand board.

Products covered by these evaluations are also used for sound insulation and in prefabricated thermal insulation systems and composite panels. The performance of systems incorporating these products is not covered by the evaluation.

The following evaluation criteria is for Type 3 products

Note:

  • The expanded polystyrene (EPS) insulation industry subscribes to an accredited certification program as part of their quality assurance. Some listings for EPS insulation products that are published in the Canadian Construction Materials Centre (CCMC) Registry may be based on the participation of one of the certification organizations accredited by the Standards Council of Canada (SCC)

Material requirements

The evaluation holder must demonstrate that the product meets the following requirements (additional requirements may be imposed by the CCMC when necessary, and are detailed in the individual evaluation):

Table 1. CAN/ULC-S701-05 Type 3 material properties
Property Unit Requirements
Thermal resistance of a 25-mm-thick specimen m 2·°C/W ≥ 0.74
Long-term thermal resistance (LTTR) Footnote (1) m 2·°C/W ≥ 1.73
Water vapour permeance for a 25-mm-thick specimen ng/(Pa·s·m 2) ≤ 130
Dimensional stability % linear change ≤ 1.5
Flexural strength kPa ≥ 300
Water absorption % by volume ≤ 2.0
Compressive strength kPa ≥ 140
Limiting oxygen index % ≥ 24


© Underwriters Laboratories of Canada Inc. Reprinted with permission. This material is not the complete and official position of ULC Standards on the referenced subject, which is represented only by the ULC Standard in its entirety.

Installation requirements

The CCMC requires that evaluation holders provide instructions for the installation of the product(s) that:

Additionally, where EPS insulation is to be used in EIFS applications, users must refer to the Annex mentioned in the standard for mandatory additional requirements.

Manufacturing requirements

The CCMC requires that evaluation holders, at a minimum, demonstrate that the associated production process:

Additionally, the expanded polystyrene (EPS) insulation industry subscribes to an accredited certification program as part of their quality assurance. Some assessments for EPS insulation products that are published in the Canadian Construction Materials Centre (CCMC) Registry are based on certification by an accredited product certification body.

Labelling requirements

The CCMC requires that evaluation holders ensure that product labels:

Additionally, the product must be marked with the following information:

  • type;
  • ULC standard number;
  • manufacturer's name or trademark; and
  • the associated CCMC number

The product must also be marked with the warning:

"Caution: This product is combustible. A protective barrier or thermal barrier is required as specified in the appropriate building code."

Classification information

Products falling within the scope of this document are commonly classified by:

MasterFormat®

  • 07 21 00 Thermal Insulation
  • 07 21 13 Board Insulation
  • 07 21 13.13 Foam Board Insulation

Published CCMC evaluations

The following products have been evaluated to these requirements by the CCMC:

CCMC number:Manufacturer:Product names:
13277-LStyro Rail Inc. Styro Rail Type 3 EPS
13317-LTrueFoam Limited TrueFoam 300
13638-LIsolofoam Group Inc. iFLEXFOAM 200, ISOLOFOAM HD30, iFLEXFOAM 300, ISOLOFOAM XHD 300, ISORAD V2 300, ISOLOFOAM HD40, ISOLOFOAM XHD 400, ISORAD V2 250, ISORAD V2 300 R3-R5, ISOLOFOAM 250, ISOLOFOAM XHD 250, ISOLOFOAM XHD 600, ISOLOFOAM Type 3

Code references

National Building Code of Canada 2010

Code references Code provision
9.15.4.1.(1)Insulating concrete form units shall be ...
9.25.2.2.(1)Except as required in , thermal insulati ...
9.36.2.4.Calculation of Effective Thermal Resistance of Assemblies
Table 5.10.1.1.Standards Applicable to Environmental Separators and Assemblies Exposed to the Exterior
Table 9.23.17.2.AWall Sheathing Thickness and Specifications
Date modified: