[CCMC evaluation requirements] CAN/ULC-S701-05, Type 1
From: National Research Council Canada
This document provides a summary of the minimum requirements imposed by the Canadian Construction Materials Centre (CCMC) for all evaluations based on the below criteria document. Additional requirements may be imposed by the CCMC when necessary for a particular evaluation, and are detailed in the individual evaluation.
Criteria document
Number | CAN/ULC-S701-05, Type 1 |
Title | Thermal Insulation, Polystyrene, Boards and Pipe Covering |
Document | Standard |
Publisher | ULC Standards |
Scope
These evaluations are of factory made rigid expanded polystyrene insulation in the form of pipe covering and boards with or without facings or coatings made by moulding (EPS) or extrusion (XPS) of expandable polystyrene beads. They include products intended for use as thermal insulation in building construction and other applications for temperatures ranging from -54°C to + 75°C. They do not include laminated products manufactured with any type of rigid board facer including fibreboard, perlite board, gypsum board, or oriented strand board.
Products covered by these evaluations are also used for sound insulation and in prefabricated thermal insulation systems and composite panels. The performance of systems incorporating these products is not covered by the evaluation.
The following evaluation criteria is for Type 1 products
Note:
- The expanded polystyrene (EPS) insulation industry subscribes to an accredited certification program as part of their quality assurance. Some listings for EPS insulation products that are published in the Canadian Construction Materials Centre (CCMC) Registry may be based on the participation of one of the certification organizations accredited by the Standards Council of Canada (SCC)
Material requirements
The evaluation holder must demonstrate that the product meets the following requirements (additional requirements may be imposed by the CCMC when necessary, and are detailed in the individual evaluation):
Property | Unit | Requirement |
---|---|---|
Thermal resistance of a 25-mm-thick specimen | m 2·°C/W | ≥ 0.65 |
Long-term thermal resistance (LTTR)Footnote (1) | m 2·°C/W | ≥ 1.73 |
Water vapour permeance for a 25-mm-thick specimenFootnote (2) | ng/(Pa·s·m2) | ≤ 300 |
Dimensional stability | % linear change | ≤ 1.5 |
Flexural strength | kPa | ≥ 170 |
Water absorption | % by volume | ≤ 6.0 |
Compressive strength | kPa | ≥ 70 |
Limiting oxygen index | % | ≥ 24 |
Additional information:
- The test methods used to determine the above material properties provide a means of comparing different cellular plastic thermal insulation. They are intended for use in specifications, product evaluation and quality control. They are not intended to predict end-use product performance.
- LTTR values for compliance are based upon 50-mm-thick product, however, as required in Clause 6.3.3.2., LTTR values shall also be reported for 25-mm and 75-mm-thick products.
© Underwriters Laboratories of Canada Inc. Reprinted with permission. This material is not the complete and official position of ULC Standards on the referenced subject, which is represented only by the ULC Standard in its entirety.
Installation requirements
The CCMC requires that evaluation holders provide instructions for the installation of the product(s) that:
- do not contravene the National Building Code of Canada, or any provincial or territorial building codes; and
- meet the requirements of CCMC minimum documentation requirements.
Manufacturing requirements
The CCMC requires that evaluation holders, at a minimum, demonstrate that the associated production process:
- is operated under a documented quality system; and
- meets the minimum requirements of the CCMC minimum documentation requirements.
Additionally, the expanded polystyrene (EPS) insulation industry subscribes to an accredited certification program as part of their quality assurance. Some assessments for EPS insulation products that are published in the Canadian Construction Materials Centre (CCMC) Registry are based on certification by an accredited product certification body.
Labelling requirements
The CCMC requires that evaluation holders ensure that product labels:
- reference the associated CCMC number or mark; and
- meet the requirements of CCMC minimum documentation requirements.
Additionally, the product must be marked with the following information:
- type;
- ULC standard number;
- manufacturer's name or trademark; and
- the associated CCMC number.
The product must also be marked with the warning:
"Caution: This product is combustible. A protective barrier or thermal barrier is required as specified in the appropriate building code."
Classification information
Products falling within the scope of this document are commonly classified by:
MasterFormat®
- 07 21 00 Thermal Insulation
- 07 21 13 Board Insulation
- 07 21 13.13 Foam Board Insulation
Published CCMC evaluations
The following products have been evaluated to these requirements by the CCMC:
CCMC number: | Manufacturer: | Product names: |
---|---|---|
12837-L | Downeast Plastics Ltd. | Thermalite Type 1 |
13393-L | HW Manufacturing Inc. | THERMAL 3Ht, QUIK-THERM™, Comfort-R |
Code references
National Building Code of Canada 2010
Code references | Code provision |
---|---|
9.15.4.1.(1) | Insulating concrete form units shall be ... |
9.25.2.2.(1) | Except as required in , thermal insulati ... |
A-9.36.2.4.(1) | Calculating the Effective Thermal Resistance of Building Envelope Assemblies |
Table 5.10.1.1. | Standards Applicable to Environmental Separators and Assemblies Exposed to the Exterior |