Compliance opinion

It is the opinion of the Canadian Construction Materials Centre that the evaluated products, when used as a roofing product installed over solid sheathing in accordance with the conditions and limitations stated in this evaluation, comply with the following code:

National Building Code of Canada 2015

ID Code provision Solution type
09-26-01-02-00-0-009.26.1.2.(1) Roofs shall be protected with roofing, i ...Acceptable
09-26-02-00-00-0-009.26.2. Roofing MaterialsAlternative

The above opinion(s) is/are based on the evaluation by the CCMC of technical evidence provided by the evaluation holder, and is bound by the stated conditions and limitations. For the benefit of the user, a summary of the technical information that forms the basis of this evaluation has been included.

Product information

Product names

  • Bellaforté Shake
  • Bellaforté Slate
  • DaVinci Multi-width Shake
  • DaVinci Multi-width Slate
  • DaVinci Single-width Shake
  • DaVinci Single-width Slate
  • Select Shake

Product description

DaVinci Multi-width Slate, DaVinci Single-width Slate, DaVinci Multi-width Shake, DaVinci Single-width Shake, Bellaforté Slate, Bellaforté Shake and Select Shake are engineered polymeric plastic-based roof tiles designed to provide the look of natural slate or shake. The products are manufactured with a proprietary formulation using thermoplastic olefins and are available in assorted colours. The DaVinci Slate shingles are manufactured in widths of 152 mm, 178 mm, 229 mm, 254 mm and 305 mm with a total length of 457 mm (152–203 mm of exposure depending on roof pitch and coursing). The DaVinci Shake shingles are manufactured in widths of 102 mm, 152 mm, 178 mm, 203 mm and 229 mm with a total length of 559 mm (229–254 mm of exposure). The Bellaforté shingles are manufactured in a single width of 346 mm and are a total length of 394–413 mm (305 mm exposed). The Select Shake shingles are manufactured in 203 mm and 254 mm widths with a total length of 559 mm (229–254 mm of exposure).

DaVinci Multi-width and DaVinci Single-width Slate

Figure 1. (a) DaVinci Multi-width Slate (b) DaVinci Single-width Slate

 

 

DaVinci Multi-width Shake and DaVinci Single-width Shake

Figure 2. (a) DaVinci Multi-width Shake (b) DaVinci Single-width Shake

 

 

Bellaforté Slate, Bellaforté Shake and Select Shake

Figure 3. (a) Bellaforté Slate (b) Bellaforté Shake (c) Select Shake

 

 

Manufacturing plant

This evaluation is valid only for products produced at the following plant:

Product namesManufacturing plant
Lenexa, KS, US
Bellaforté ShakeProduct evaluated by the CCMC
Bellaforté SlateProduct evaluated by the CCMC
DaVinci Multi-width ShakeProduct evaluated by the CCMC
DaVinci Multi-width SlateProduct evaluated by the CCMC
DaVinci Single-width ShakeProduct evaluated by the CCMC
DaVinci Single-width SlateProduct evaluated by the CCMC
Select ShakeProduct evaluated by the CCMC

Product evaluated by the CCMC Indicates that the product from this manufacturing facility has been evaluated by the CCMC

  Conditions and limitations

The CCMC’s compliance opinion is bound by this product being used in accordance with the conditions and limitations set out below.

  • The products must be installed on roofs having a minimum slope of 1-in-4. The manufacturer does not recommend installation on lower slopes.
  • For 3-in-12 to 4-in-12 roof slopes, DaVinci products must be installed with self-adhered waterproofing underlayment over the entire deck.
  • For roof slopes greater than 4-in-12, the products must be used in conjunction with an underlayment consisting of a minimum of two layers of Type 15 or one layer of Type 30 organic felt installed in accordance with the manufacturer’s installation instructions.
  • Adequate ventilation in the roof space must be provided in accordance with Article 9.19.1.1., Required Venting, of Division B of the NBC 2015.
  • Existing roofing material must be torn off prior to application. The products must be applied to a clean, dry deck.
  • The products must be installed over solid sheathing complying with the requirements of Subsection 9.23.16., Roof Sheathing, of Division B of the NBC 2015.
  • For roof slopes greater than 6-in-12, the products must be used in conjunction with self-adhered modified bituminous eave protection complying with the requirements of Subsection 9.26.5., Eave Protection for Shingles and Shakes, of Division B of the NBC 2015.
  • The products must be installed with stainless steel, hot-dipped galvanized, solid copper, corrosion-resistant fasteners that are at least 38-mm long. The fasteners must penetrate 19 mm into wood decking or at least 5 mm through plywood or oriented strandboard (OSB) sheathing.
  • The products have dimpled nail pocket locations to facilitate hand nailing and the correct positioning of fasteners. Two fasteners per shingle are required, one placed in each of the nail pockets.
  • For Bellaforte shingles, in addition to the two fasteners per shingle required in the dimpled nail pocket, one additional nail is required in the nailing tab where the tab interlocks with the adjacent shingle.
  • The products must be installed in strict conformance with the manufacturer’s installation instructions.
  • DaVinci Slate and Shake products should not be used on vertical applications or mansard roofs.
  • The products or their packaging must be clearly identified with the phrase “CCMC 14094 -R.”

  Technical information

This evaluation is based on demonstrated conformance with the following criteria:

Evaluation requirements
Criteria number Criteria name
CCMC-TG-073226.01-15CCMC Technical Guide for Recycled Thermoplastic Composite Simulated Roofing, Slate Tiles

The evaluation holder has submitted technical documentation for the CCMC’s evaluation. Testing was conducted at laboratories recognized by the CCMC. The corresponding technical evidence for these products is summarized below.

Prescriptive requirements
Table 1. Results of testing the prescriptive requirements of the products
Property Unit Requirement Result
Density g/cm3 Report value 1.50
Impact izod J/m ≥ 60 274
Dimensional stability % Max. 5.0 Pass
Water absorption % Max. 3.0 (by volume) 0.0
Flexural strength MPa Report value 15.4
Flexural modulus MPa ≥ 550 1 151
Tensile strength MPa ≥ 15 7.7Table footnote (1)
Ozone resistance - No visible cracks Pass
Hardness Barcol Report value 9

 

Performance requirements
Table 2. Results of testing the performance requirements of the products
Property Requirement Result
Acid rain Resist sulfate ion diffusion Pass
Dynamic impact at 23°C ± 2°C No deleterious effects, such as cracking, flaking, etc. Pass
Dynamic impact at −40°C ± 2°C No deleterious effects, such as cracking, flaking, etc. Pass
Uplift bend (optional) DaVinci Slate

 

 

Minimum of two times the tile weight; no cracking, breaking or falling off (specimen from deck)

FailTable footnote (1)
DaVinci Shake FailTable footnote (1)
Select Shake FailTable footnote (1)
Bellaforté Slate Pass
Bellaforté Shake Pass
Traffic load (N) > 900 Pass
Nail pull through (N) > 440 476
Accelerated weathering – flexural strength after 1 000 h of exposure (%) 90% retention of original, no defects other than colour change 91
Accelerated weathering – flexural strength after 2 000 h of exposure (%) 80% retention of original, no defects other than colour change 93
Accelerated weathering – flexural strength after 5 000 h of exposure (%) Report value 96
Heat aging – flexural strength (%) ≥ 80% retention of original 86.5
Freeze/thaw (24 cycles) Testing not required based on water absorption test results N/A

 

Table 3. Results of testing the wind uplift resistance of the products
Property Requirement Result
Interval 1 (80 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 2 (0 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 3 (100 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 4 (0 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 5 (120 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 6 (0 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 7 (140 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 8 (0 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 9 (170 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 10 (0 km/h for 15 min) No loss of integrity or damage noted Pass

 

Table 4. Results of testing the dynamic pressure of water infiltration of the products
Property Requirement Result
Interval 1 (wind speed 50 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 2 (wind speed 0 km/h for 10 min) No loss of integrity or damage noted Pass
Interval 3 (wind speed 100 km/h for 15 min) No loss of integrity or damage noted Pass
Interval 4 (wind speed 0 km/h for 10 min) No loss of integrity or damage noted Pass
Interval 5 (wind speed 140 km/h for 5 min) No loss of integrity or damage noted Pass
Interval 6 (wind speed 0 km/h for 10 min) No loss of integrity or damage noted Pass
Interval 7 (wind speed 170 km/h for 5 min) No loss of integrity or damage noted Pass
Interval 8 (wind speed 0 km/h for 10 min) No loss of integrity or damage noted Pass

 

 

Administrative information

Use of Canadian Construction Materials Centre (CCMC) assessments

This assessment must be read in the context of the entire CCMC Registry of Product Assessments, any applicable building code or by-law requirements, and/or any other regulatory requirements (for example, the Canada Consumer Product Safety Act, the Canadian Environmental Protection Act, etc.).

It is the responsibility of the user to confirm that the assessment they are using is current and has not been withdrawn or superseded by a later version on the CCMC Registry of Product Assessments.

Disclaimer

The National Research Council of Canada (NRC) has evaluated only the characteristics of the specific product described herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (such as authorities having jurisdiction, design professionals and specifiers). This evaluation is valid when the product is used as part of permitted construction, respecting all conditions and limitations stated in the evaluation, and in accordance with applicable building codes and by-laws.

This evaluation is provided without representation, warranty or guarantee of any kind, expressed or implied, and the NRC provides no endorsement for any evaluated product. The NRC accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained herein or the use of any evaluated product. The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.

Language

Une version française de ce document est disponible.
In the case of any discrepancy between the English and French version of this document, the English version shall prevail.

Copyright

© His Majesty the King in Right of Canada, as represented by the National Research Council of Canada, 2023

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the CCMC.

Date modified: