[CCMC 13626-L] CCMC Standard compliance evaluation
From: National Research Council Canada

CCMC number: | 13626-L |
Status: | Active |
Issue date: | 2013-06-05 |
Modified date: | 2022-11-17 |
Evaluation holder: | ICP Construction Inc.
150 Dascomb Road |
Product names: |
|
Evaluation requirements: |
In most jurisdictions this document is sufficient evidence for approval by Canadian authorities.
Learn more about CCMC recognition Look for the trusted CCMC mark on products to verify compliance.Product information
Product names
- Fast Foam Extreme Sealant
- Fast Foam Fireblock
- Fast Foam Window and Door Sealant
- Handi-Foam Black Sealant
- Handi-Foam Extreme
- Handi-Foam Extreme Window and Door
- Handi-Foam Fireblock
- Handi-Foam HC Foam Sealant (Gun Foam and Straw Foam versions)
Product description
The products are one-component polyurethane expanding foams, which can be used as sealants to control air leakage at penetrations (e.g., in window and door frames) within the DuPont® Tyvek® Homewrap™ air barrier system. The products are packaged in pressurized containers, which are available in various sizes.
The durability of the products was assessed with the following substrates at the window/wall interface.
Component | Result | |
---|---|---|
Window or door frame | Air barrier material | |
Wood | DuPont® Tyvek® Homewrap™ | Pass |
Vinyl | DuPont® Tyvek® Homewrap™ | Pass |
Manufacturing plant
This evaluation is valid only for products produced at the following plant:
Product names | Manufacturing plant |
---|---|
Norton, OH, US | |
Fast Foam Extreme Sealant | - |
Fast Foam Fireblock | - |
Fast Foam Window and Door Sealant | Product evaluated by the CCMC |
Handi-Foam Black Sealant | Product evaluated by the CCMC |
Handi-Foam Extreme | Product evaluated by the CCMC |
Handi-Foam Extreme Window and Door | Product evaluated by the CCMC |
Handi-Foam Fireblock | Product evaluated by the CCMC |
Handi-Foam HC Foam Sealant (Gun Foam and Straw Foam versions) | Product evaluated by the CCMC |
Product evaluated by the CCMC Indicates that the product from this manufacturing facility has been evaluated by the CCMC
Technical information
This evaluation is based on demonstrated conformance with the following criteria:
Criteria number | Criteria name |
---|---|
CAN/ULC-S710.1-11, Class 1 | Standard for Thermal Insulation – Bead-Applied One Component Polyurethane Air Sealant Foam, Part 1: Material Specification |
The products containing the word “Fireblock” as part of the name have not been evaluated to conform to Sentence 3.1.11.7.(1) of the National Building Code of Canada 2010 (NBC 2010). As such, the products have not been tested to CAN/ULC-S101, “Fire Endurance Tests of Building Construction and Materials” to obtain a fire resistance rating.
As per CAN/ULC-S710.1-11, the one-component air sealant foam must be installed in accordance with the manufacturer’s instructions and CAN/ULC-S710.2-11, “Standard for Thermal Insulation – Bead-Applied One Component Polyurethane Air Sealant Foam – Part 2: Installation.”
The time period before occupancy is one (1) day plus one (1) hour.
Administrative information
Disclaimer
This evaluation is issued by the Canadian Construction Materials Centre (CCMC), part of the Construction Research Centre at the National Research Council of Canada (NRC). The evaluation must be read in the context of the entire CCMC Registry of Product Assessments and the legislated applicable building code in effect.
The CCMC was established in 1988 on behalf of the applicable regulator (i.e., the provinces and territories) to ensure—through assessment—conformity of alternative and acceptable solutions to regional building codes as determined by the local authority having jurisdiction (AHJ) as part of the issuance of a building permit.
It is the responsibility of the local AHJs, design professionals, and specifiers to confirm that the evaluation is current and has not been withdrawn or superseded by a later issue. Please refer to the website or contact:
Canadian Construction Materials Centre
Construction Research Centre
National Research Council of Canada
1200 Montreal Road
Ottawa, Ontario, K1A 0R6
Telephone: 613-993-6189
Fax: 613-952-0268
The NRC has evaluated the material, product, system or service described herein only for those characteristics stated herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (i.e., AHJs, design professionals and specifiers). This evaluation is only valid when the product is installed in strict compliance with the stated conditions and limitations of evaluation and the applicable local building code. In circumstances where no applicable local building permit is issued and that no confirmation of compliance ‘for use in the intended field application’ is undertaken, this evaluation is null and void in all respects. This evaluation is provided without representation, warranty, or guarantee of any kind, expressed, or implied, and the NRC provides no endorsement for any evaluated material, product, system or service described herein. The NRC accepts no responsibility whatsoever arising in any way from any and all use and reliance on the information contained in this evaluation with respect to its compliance to the referenced code(s) and standard(s). The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.
Language
Une version française de ce document est disponible.
In the case of any discrepancy between the English and French version of this document, the English version shall prevail.
Copyright
© His Majesty the King in Right of Canada, as represented by the National Research Council of Canada, 2022
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the CCMC.