[CCMC 13387-R] CCMC Canadian code compliance evaluation

In most jurisdictions this document is sufficient evidence for approval by Canadian authorities.

Learn more about CCMC recognition Look for the trusted CCMC mark on products to verify compliance.

Compliance opinion

It is the opinion of the Canadian Construction Materials Centre that the evaluated product, when used as a drainage layer against the outside of the foundation wall to protect the wall from transient or intermittent water that may come in contact with the wall surface, in accordance with the conditions and limitations stated in this evaluation, complies with the following code:

Ontario Building Code 2017

ID Code provision Solution type
09-14-02-01-02-b-009.14.2.1.(2)(b) Foundation Wall DrainageAlternative

Ruling No. 11-10-268 (13387-R) authorizing the use of this product in Ontario, subject to the terms and conditions contained in the Ruling, was made by the Minister of Municipal Affairs and Housing on 2011-09-20 (revised 2017-01-10) pursuant to s.29 of the Building Code Act, 1992 (see Ruling for terms and conditions). This Ruling is subject to periodic revisions and updates.


The above opinion(s) is/are based on the evaluation by the CCMC of technical evidence provided by the evaluation holder, and is bound by the stated conditions and limitations. For the benefit of the user, a summary of the technical information that forms the basis of this evaluation has been included.

Product information

Product name

Foamular® C-200 Cel-Drain

Product description

The product is a Type 3, extruded polystyrene, rigid thermal insulation panel with specially designed vertical grooves that drain water down to the footing drainage system, directing water away from the foundation wall. The panels measure 600 mm wide × 2 400 mm long × 63.5 mm or 102 mm thick. The grooved channels measure 6 mm deep × 19 mm wide. The groove spacing is at 50 mm on centre (o.c.). The product is made from Foamular® thermal insulation, which is a pink-tinted, extruded/expanded polystyrene product that meets the requirements of CAN/ULC-S701-11, “Thermal Insulation, Polystyrene, Boards and Pipe Covering” (see CCMC 13431-L).

Installation of the Foamular® C-200 Cel-Drain extruded polystyrene.
Figure 1. Below-grade installation of the product
  1. Insulation
  2. Caulking/sealant
  3. Polyethylene sealing strip
  4. Foamular® C-200 Cel-Drain extruded polystyrene
Installation of the Foamular® C-200 Cel-Drain extruded polystyrene for above and below grade.
Figure 2. Below and above-grade installation of the product
  1. Above-grade protection
  2. Attachment channel
  3. Foamular® C-200 Cel-Drain extruded polystyrene
  4. Dampproofing

Manufacturing plants

This evaluation is limited to products produced at the following plants:

Product nameManufacturing plants
Grande-Île (Valleyfield), QC, CAPortland, OR, US
Foamular® C-200 Cel-DrainProduct evaluated by the CCMCProduct evaluated by the CCMC

Product evaluated by the CCMC Indicates that the product from this manufacturing facility has been evaluated by the CCMC

  Conditions and limitations

The CCMC’s compliance opinion is bound by this product being used in accordance with the conditions and limitations set out below.

  • The product is designed to direct water to the footing drainage system when installed against the foundation wall. The drainage surface (grooved side) is installed directly against the dampproofing face of the foundation wall with the drainage grooves in the vertical position (Class B).
  • This drainage product is one part of the total foundation drainage system that consists of a combination of design and construction processes that use different products. For example, a well-functioning footing drain (weeping tile) is required to direct water away from the bottom of the foundation wall.
  • The placement and grading of backfill must conform to Subsection 9.12.3., Backfill, of Division B of the OBC 2012.
  • The product has been evaluated for use in depths up to 3.7 m below grade (Type 2).
  • There must be a 6 mm to 13 mm gap between the bottom edge of the insulation and the top surface of the footing to facilitate the emptying of water from the drainage layer to the drain tile.
  • The top surface of the panels must be sealed with an ultraviolet stabilized polyethylene sheet and an acoustical sealant to prevent soil from entering the drainage channels. The polyethylene sheet must be wide enough (minimum 15 mm) to drape over the front and back of the panels.
  • The top surface of the panels must be within 75 mm of the finished grade.
  • The product packaging must be clearly identified with the phrase “CCMC 13387-R.

  Technical information

This evaluation is based on demonstrated conformance with the following criteria:

Evaluation requirements
Criteria number Criteria name
CCMC-TG-334613.02-12CCMC Technical Guide for Foundation Drainage Systems

 

The Report Holder has submitted technical documentation for the CCMC evaluation. Testing was conducted at laboratories recognized by the CCMC. The corresponding technical evidence for this product is summarized below.

Results of testing the performance requirements of the product
Property Unit Requirement Result
Side water inflow min 500 mL of water in less than 15 min 6
Deformation under compressive load mm Minimum 10 62

Administrative information

Use of Canadian Construction Materials Centre (CCMC) assessments

This assessment must be read in the context of the entire CCMC Registry of Product Assessments, any applicable building code or by-law requirements, and/or any other regulatory requirements (for example, the Canada Consumer Product Safety Act, the Canadian Environmental Protection Act, etc.).

It is the responsibility of the user to confirm that the assessment they are using is current and has not been withdrawn or superseded by a later version on the CCMC Registry of Product Assessments.

Disclaimer

The National Research Council of Canada (NRC) has evaluated only the characteristics of the specific product described herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (such as authorities having jurisdiction, design professionals and specifiers). This evaluation is valid when the product is used as part of permitted construction, respecting all conditions and limitations stated in the evaluation, and in accordance with applicable building codes and by-laws.

This evaluation is provided without representation, warranty or guarantee of any kind, expressed or implied, and the NRC provides no endorsement for any evaluated product. The NRC accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained herein or the use of any evaluated product. The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.

Language

Une version française de ce document est disponible.
In the case of any discrepancy between the English and French version of this document, the English version shall prevail.

Copyright

© His Majesty the King in Right of Canada, as represented by the National Research Council of Canada, 2024

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the CCMC.

Page details

From: National Research Council Canada

Date modified: