Language selection

Search


[CCMC 13266-L] CCMC Standard compliance evaluation

From: National Research Council Canada

In most jurisdictions this document is sufficient evidence for approval by Canadian authorities.

Learn more about CCMC recognition Look for the trusted CCMC mark on products to verify compliance.

Product information

Product names

  • Elevate FullForce™
  • Elevate RubberGard™ EcoWhite™ EPDM
  • Elevate RubberGard™ EcoWhite™ EPDM PT
  • Elevate RubberGard™ EcoWhite™ Platinum™ EPDM
  • Elevate RubberGard™ EcoWhite™ Platinum™ EPDM PT
  • Elevate RubberGard™ LSFR PT
  • Elevate RubberGard™ Low Slope Fire Retardant (Black)
  • Elevate RubberGard™ Max EPDM
  • Elevate RubberGard™ Max PT
  • Elevate RubberGard™ Platinum
  • Elevate RubberGard™ Platinum PT

Product description

Type I

The following membranes are single-ply, non-reinforced, ethylene/propylene diene terpolymer (EPDM) roofing membranes available in many thicknesses, widths and lengths:

  • Elevate RubberGard™ Low Slope Fire Retardant (Black)
  • Elevate RubberGard™ LSFR PT
  • Elevate RubberGard™ Platinum
  • Elevate RubberGard™ Platinum PT
  • Elevate FullForce™ EPDM

Elevate RubberGard™ Platinum PT and the Elevate RubberGard™ LSFR PT have a 76.2 mm (3 in.) or 152.4 mm (6 in.) wide QuickSeamTM tape that is factory-laminated continuously along one 30.5 m (100 ft.) length of the panel.

The Elevate FullForce™ EPDM membrane is a self-adhered roof system with Secure Bond Adhesive that is factory-applied to ensure uniform adhesion across the entire membrane.

The following membranes are single-ply, non-reinforced, bi-laminate, white-on-black, cured EPDM roofing membranes:

  • Elevate RubberGard™ EcoWhite™ EPDM
  • Elevate RubberGard™ EcoWhite™ EPDM PT
  • Elevate RubberGard™ EcoWhite™ Platinum™ EPDM
  • Elevate RubberGard™ EcoWhite™ Platinum™ EPDM PT

Elevate RubberGard™ EcoWhite™ EPDM is 1.52 mm (0.060 in.) thick and comes in lengths of 15.24 m (50 ft.) and 30.5 m (100 ft.), and widths of 3.05 m (10 ft.), 5.08 m (16 ft. 8 in.), 6.1 m (20 ft.), 7.6 m (25 ft.) and 9.4 m (30 ft.).

Elevate RubberGard™ EcoWhite™ EPDM PT has a 76 mm (3 in.) wide QuickSeam™ tape that is factory-laminated continuously along one 30.5 m (100 ft.) length of the panel.

Elevate RubberGard™ EcoWhite™ Platinum™ EPDM is 2.29 mm (0.090 in.) thick and comes in lengths of 15.24 m (50 ft.) and 30.5 m (100 ft.), with a width of 3.05 m (10 ft.).

Elevate RubberGard™ EcoWhite™ Platinum™ PT has either a 76 mm (3 in.) or 152.4 mm (6 in.) wide QuickSeam™ tape that is factory-laminated continuously along one 30.5 m (100 ft.) length of the panel.

Type II

Elevate RubberGard™ Max EPDM and Elevate RubberGard™ Max PT membranes are single-ply, reinforced, black, EPDM roofing membranes that are 3.05 m (10 ft.) wide and 30.5 m (100 ft.) long. Elevate RubberGard™ Max is available in thicknesses of 1.14 mm (45 mil), 1.52 mm (60 mil) and 1.91 mm (75 mil), and Elevate RubberGard™ Max PT is only available in a thickness of 1.52 mm (60 mil).

Elevate RubberGard™ Max PT has a 152.4 mm (6 in.) wide QuickSeam™ tape that is factory-laminated continuously along one 30.5 m (100 ft.) length of the panel.

Manufacturing plant

This evaluation is valid only for products produced at the following plant:

Product namesManufacturing plant
Prescott, AR, US
Elevate FullForce™Product evaluated by the CCMC
Elevate RubberGard™ EcoWhite™ EPDMProduct evaluated by the CCMC
Elevate RubberGard™ EcoWhite™ EPDM PTProduct evaluated by the CCMC
Elevate RubberGard™ EcoWhite™ Platinum™ EPDMProduct evaluated by the CCMC
Elevate RubberGard™ EcoWhite™ Platinum™ EPDM PTProduct evaluated by the CCMC
Elevate RubberGard™ LSFR PTProduct evaluated by the CCMC
Elevate RubberGard™ Low Slope Fire Retardant (Black)Product evaluated by the CCMC
Elevate RubberGard™ Max EPDMProduct evaluated by the CCMC
Elevate RubberGard™ Max PTProduct evaluated by the CCMC
Elevate RubberGard™ PlatinumProduct evaluated by the CCMC
Elevate RubberGard™ Platinum PTProduct evaluated by the CCMC

Product evaluated by the CCMC Indicates that the product from this manufacturing facility has been evaluated by the CCMC

  Technical information

This evaluation is based on demonstrated conformance with the following criteria:

Evaluation requirements
Criteria number Criteria name
ASTM D4637/D4637M -13, Type IStandard Specification for EPDM Sheet Used in Single-Ply Roof Membrane
ASTM D4637/D4637M -13, Type IIStandard Specification for EPDM Sheet Used in Single-Ply Roof Membrane
ASTM D4637/D4637M-15, Type IStandard Specification for EPDM Sheet Used in Single-Ply Roof Membrane

Additional information

Fire protection

No information at this time.

Wind uplift resistance of membrane roofing assemblies

The wind uplift resistance performance rating is based on CAN/CSA A123.21-14, “Dynamic Wind Uplift Resistance of Membrane-Roofing Systems.”

Table 1. Wind uplift performance ratingTable footnote footnote (1)
Product AARSTable footnote footnote (2) – factored load kPa (psf) MARSTable footnote footnote (3) – factored load kPa (psf) PARSTable footnote footnote (4) – factored load kPa (psf)
Elevate RubberGard™ Low Slope Fire Retardant (Black) –2.4 (–50) or –3.9 (–66.7)
Table footnote footnote (5)Table footnote footnote (6)
–3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)
Elevate FullForce™ –2.4 (–50) or –3.9 (–66.7)
Table footnote footnote (5)Table footnote footnote (6)
–3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ Max –2.4 (–50) or –3.9 (–66.7)
Table footnote footnote (5)Table footnote footnote (6)
–2.9 (–60)Table footnote footnote (9) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ Max PT –2.4 (–50) or –3.9 (–66.7)
Table footnote footnote (5)Table footnote footnote (6)
–2.9 (–60)Table footnote footnote (9) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ EcoWhite™ EPDM –2.4 (–50) or –3.9 (–66.7)
Table footnote footnote (5)Table footnote footnote (6)
–3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ EcoWhite™ EPDM PT –2.4 (–50) or –3.9 (–66.7)
Table footnote footnote (5)Table footnote footnote (6)
–3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ EcoWhite™ Platinum™ EPDM –2.4 (–50) or –3.9 (–66.7)
Table footnote footnote (5)Table footnote footnote (6)
–3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ EcoWhite™ Platinum™ EPDM PT –2.4 (–50) or –3.9 (–66.7)
Table footnote footnote (5)Table footnote footnote (6)
–3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ Platinum –2.0 (–41)Table footnote footnote (10) –3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ Platinum PT –2.0 (–41)Table footnote footnote (10) –3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)
Elevate RubberGard™ LSFR PT –2.0 (–41)Table footnote footnote (10) –3.2 (–67)Table footnote footnote (7) –3.2 (–67)Table footnote footnote (8)

Administrative information

Disclaimer

This evaluation is issued by the Canadian Construction Materials Centre (CCMC), part of the Construction Research Centre at the National Research Council of Canada (NRC). The evaluation must be read in the context of the entire CCMC Registry of Product Assessments and the legislated applicable building code in effect.

The CCMC was established in 1988 on behalf of the applicable regulator (i.e., the provinces and territories) to ensure—through assessment—conformity of alternative and acceptable solutions to regional building codes as determined by the local authority having jurisdiction (AHJ) as part of the issuance of a building permit.

It is the responsibility of the local AHJs, design professionals, and specifiers to confirm that the evaluation is current and has not been withdrawn or superseded by a later issue. Please refer to the website or contact:

Canadian Construction Materials Centre
Construction Research Centre
National Research Council of Canada
1200 Montreal Road
Ottawa, Ontario, K1A 0R6
Telephone: 613-993-6189
Fax: 613-952-0268

The NRC has evaluated the material, product, system or service described herein only for those characteristics stated herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (i.e., AHJs, design professionals and specifiers). This evaluation is only valid when the product is installed in strict compliance with the stated conditions and limitations of evaluation and the applicable local building code. In circumstances where no applicable local building permit is issued and that no confirmation of compliance ‘for use in the intended field application’ is undertaken, this evaluation is null and void in all respects. This evaluation is provided without representation, warranty, or guarantee of any kind, expressed, or implied, and the NRC provides no endorsement for any evaluated material, product, system or service described herein. The NRC accepts no responsibility whatsoever arising in any way from any and all use and reliance on the information contained in this evaluation with respect to its compliance to the referenced code(s) and standard(s). The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.

Language

Une version française de ce document est disponible.
In the case of any discrepancy between the English and French version of this document, the English version shall prevail.

Copyright

© His Majesty the King in Right of Canada, as represented by the National Research Council of Canada, 2022

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the CCMC.