Compliance opinion

It is the opinion of the Canadian Construction Materials Centre that the evaluated product, when used as a breather-type sheathing membrane in accordance with the conditions and limitations stated in this evaluation, complies with the following code:

National Building Code of Canada 2015

ID Code provision Solution type
09-27-03-02-00-0-009.27.3.2. Sheathing Membrane Material StandardAlternative

The above opinion(s) is/are based on the evaluation by the CCMC of technical evidence provided by the evaluation holder, and is bound by the stated conditions and limitations. For the benefit of the user, a summary of the technical information that forms the basis of this evaluation has been included.

Product information

Product name

SRP AirOutshield™ - Sheathing Membrane

Product description

The product is manufactured by thermally bonding two spun-bonded polypropylene fabrics with a microporous film between the two layers to form a breathable waterproof membrane.

The product is 0.5 mm thick and has a white inner face and a black exterior. It is available in rolls that are 1.5 m wide and 50 m long.

Manufacturing plant

This evaluation is valid only for products produced at the following plant:

Product nameManufacturing plant
Przyw, Poland, Poland
SRP AirOutshield™ - Sheathing MembraneProduct evaluated by the CCMC

Product evaluated by the CCMC Indicates that the product from this manufacturing facility has been evaluated by the CCMC

  Conditions and limitations

The CCMC’s compliance opinion is bound by this product being used in accordance with the conditions and limitations set out below.

  • The product can be used as a breather-type sheathing membrane under commonly used types of exterior cladding to reduce the risk of water infiltration. The main purpose of the membrane is to create a continuous envelope around the occupied areas of residential or light commercial construction. Such continuity is achieved by overlapping or sealing the product either to itself using the CCMC-evaluated contractor sheathing tape, or to other construction materials using an acoustical sealant.
  • A conforming installation must be:
    • installed with the printed side facing outward;
    • protected within 60 days from exposure to ultraviolet (UV) radiation from the sun;
    • installed according to Article 9.27.3.3., Required Sheathing Membrane and Installation, of Division B of the NBC 2015, and in accordance with the manufacturer’s current instructions;
    • installed with a minimum air space of 10 mm between the sheathing membrane and the cladding, unless the cladding does not require an air space (i.e., as deemed by the CCMC or by building officials based on past cladding performance); and
    • installed with the material overlapping 100 mm at vertical joints and 100 mm at horizontal joints. Note that joints must be taped and the material must be sealed around both window and door openings.
  • A concealed air space exceeding 25 mm in width must contain proper fire blocks in accordance with Subsection 9.10.16., Fire Blocks, of Division B of the NBC 2015.
  • The product must be clearly identified with the phrase “CCMC 13549-R.”

  Technical information

This evaluation is based on demonstrated conformance with the following criteria:

Evaluation requirements
Criteria number Criteria name
CCMC-TG-072510.03-15CCMC Technical Guide for Sheathing Membrane, Breather Type

The Report Holder has submitted technical documentation for the CCMC’s evaluation. Testing was conducted at laboratories recognized by the CCMC. The corresponding technical evidence for this product is summarized below.

Material requirements
Table 1. Results of testing of material property for the product
Property Unit Requirement Result
Sheet width (tolerance)  mm ≥ –6 Pass
Performance requirements
Table 2. Results of testing of performance requirements for the product
Property Unit Requirement Result
Tensile strength  N/mm ≥ 3.5 4.79
Water vapour permeanceTable footnote (1) ng/(Pa·s·m2) ≥ 170 4 808
Water ponding (original)  - No leakage PassTable footnote (2)
Tensile strength (% retention of original) after UV exposure % ≥ 90 93.7
Tensile strength (% retention of original) after UV exposure and heat aging % ≥ 85 90.6
Water vapour permeance after UV exposure and heat aging ng/(Pa·s·m2) ≥ 170 10 433
Water ponding after UV exposure and heat aging - No leakage PassTable footnote (2)

Administrative information

Use of Canadian Construction Materials Centre (CCMC) assessments

This assessment must be read in the context of the entire CCMC Registry of Product Assessments, any applicable building code or by-law requirements, and/or any other regulatory requirements (for example, the Canada Consumer Product Safety Act, the Canadian Environmental Protection Act, etc.).

It is the responsibility of the user to confirm that the assessment they are using is current and has not been withdrawn or superseded by a later version on the CCMC Registry of Product Assessments.

Disclaimer

The National Research Council of Canada (NRC) has evaluated only the characteristics of the specific product described herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (such as authorities having jurisdiction, design professionals and specifiers). This evaluation is valid when the product is used as part of permitted construction, respecting all conditions and limitations stated in the evaluation, and in accordance with applicable building codes and by-laws.

This evaluation is provided without representation, warranty or guarantee of any kind, expressed or implied, and the NRC provides no endorsement for any evaluated product. The NRC accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained herein or the use of any evaluated product. The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.

Language

Une version française de ce document est disponible.
In the case of any discrepancy between the English and French version of this document, the English version shall prevail.

Copyright

© His Majesty the King in Right of Canada, as represented by the National Research Council of Canada, 2024

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the CCMC.

Page details

From: National Research Council Canada

Date modified: