[CCMC 13198-R] CCMC Canadian code compliance evaluation
From: National Research Council Canada

CCMC number: | 13198-R |
Status: | Active |
Issue date: | 2005-07-11 |
Modified date: | 2023-11-15 |
Evaluation holder: | Blow-In-Blanket®
14100 East 35th Place, Suite 104 |
Product name: | Blow-In-Blanket® System (BIBS®) – Dry |
Compliance: | NBC 2015, OBC |
Criteria: |
|
In most jurisdictions this document is sufficient evidence for approval by Canadian authorities.
Learn more about CCMC recognition Look for the trusted CCMC mark on products to verify compliance.Compliance opinion
It is the opinion of the Canadian Construction Materials Centre that the evaluated product, when used as a means to install thermal insulation in accordance with the conditions and limitations stated in this evaluation, complies with the following code:
National Building Code of Canada 2015
ID | Code provision | Solution type |
---|---|---|
09-25-02-02-01-e-00 | 9.25.2.2.(1) Insulation Materials | Acceptable |
09-25-02-04-00-0-00 | 9.25.2.4.(4) Where blown-in insulation is installed i ... | Acceptable |
Ontario Building Code
Ruling No. 11-03-261 (13198-R) authorizing the use of this product in Ontario, subject to the terms and conditions contained in the Ruling, was made by the Minister of Municipal Affairs and Housing on 2011-05-30 (revised 2011-08-16) pursuant to s.29 of the Building Code Act, 1992 (see Ruling for terms and conditions). This Ruling is subject to periodic revisions and updates.
The above opinion(s) is/are based on the evaluation by the CCMC of technical evidence provided by the evaluation holder, and is bound by the stated conditions and limitations. For the benefit of the user, a summary of the technical information that forms the basis of this evaluation has been included.
Product information
Product name
Blow-In-Blanket® System (BIBS®) – Dry
Product description
Using the injection equipment, the loose-fill thermal insulation material is dry-blown into each wall cavity through a pre-cut hole in the nylon netting. The nylon netting, which is used to contain the insulation after installation, is stapled to the interior side of the wood-frame structure.
Figure 1. Blow-In-Blanket® System (BIBS®) – Dry
Conditions and limitations
The CCMC’s compliance opinion is bound by this product being used in accordance with the conditions and limitations set out below.
- This evaluation applies to Part 9, Housing and Small Buildings, of Division B of the NBC 2015 using conventional wood-frame wall construction.
- The system must be used with thermal insulation that
- is listed with a CCMC-recognized certification program,
- has a CCMC number, or
- has evidence that the product complies with CAN/ULC-S702-09, “Mineral Fibre Thermal Insulation for Buildings.”
- The following products have been pre-approved by Blow-In-Blanket® as acceptable thermal insulation to be used in the Blow-In-Blanket® System (BIBS®) – Dry system:
- Johns Manville Climate Pro and Attic Protector Blowing Wool Insulation (CCMC 12642-L),
- Jet Stream® MAX , CCMC 13404-L, JetStream® MAX Blowing Insulation Wall System (CCMC 13422-R),
- InsulSafe® XC Wall Insulation System (CCMC 13272-R), and
- Johns Manville Spider® Plus Custom Insulation System (CCMC 13212-R).
- Installers must be manufacturer-approved, must use approved equipment, and must follow the conditions and limitations specified in this Report.
- The thermal insulation product must be delivered to the building site in unopened packages.
- The netting must not bulge more than 13 mm beyond the stud in order to provide the necessary product density.
- The insulation must be kept away from heat-emitting devices, such as recessed light fixtures, chimneys, and propane or natural gas sources, at a distance of at least 75 mm or the distance required by the local authority having jurisdiction (AHJ).
- The installation must be in accordance with the manufacturer’s installation instructions
- For coverage charts, refer to product literature from the respective thermal insulation manufacturers.
- The products used with the Blow-In-Blanket® System (BIBS®) – Dry system shall be clearly identified with the CCMC # and manufacturer name.
Technical information
This evaluation is based on demonstrated conformance with the following criteria:
Criteria number | Criteria name |
---|---|
CCMC-TG-072126.02-15 | CCMC Technical Guide for Blown Mineral Fibre Insulation System with Netting for Walls |
Material requirements
The thermal insulation product meets the requirements in CAN/ULC-S702, Type 5.
Performance requirements
Property |
Unit |
Requirement |
Result |
|
---|---|---|---|---|
Bulge |
38 mm × 89 mm: studs at 400 mm on centre (o.c.) |
mm |
13 |
Pass |
38 mm × 140 mm: studs at 600 mm o.c. |
mm |
13 |
Pass |
|
Design density |
38 mm × 89 mm: studs at 400 mm o.c. |
kg/m3 |
≥ 25 or proponent's design density |
Pass |
38 mm × 140 mm: studs at 600 mm o.c. |
kg/m3 |
≥ 25 or proponent's design density |
Pass |
|
Density deviation from each stud space |
38 mm × 89 mm: studs at 400 mm o.c. |
% |
± 10% of design density |
Pass |
38 mm × 140 mm: studs at 600 mm o.c. |
% |
± 10% of design density |
Pass |
|
Thermal resistance at 150 mm |
38 mm × 89 mm: studs at 400 mm o.c. |
m2·K/W |
≥ 3.6 |
Pass |
38 mm × 140 mm: studs at 600 mm o.c. |
m2·K/W |
≥ 3.6 |
Pass |
Administrative information
Use of Canadian Construction Materials Centre (CCMC) assessments
This assessment must be read in the context of the entire CCMC Registry of Product Assessments, any applicable building code or by-law requirements, and/or any other regulatory requirements (for example, the Canada Consumer Product Safety Act, the Canadian Environmental Protection Act, etc.).
It is the responsibility of the user to confirm that the assessment they are using is current and has not been withdrawn or superseded by a later version on the CCMC Registry of Product Assessments.
Disclaimer
The National Research Council of Canada (NRC) has evaluated only the characteristics of the specific product described herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (such as authorities having jurisdiction, design professionals and specifiers). This evaluation is valid when the product is used as part of permitted construction, respecting all conditions and limitations stated in the evaluation, and in accordance with applicable building codes and by-laws.
This evaluation is provided without representation, warranty or guarantee of any kind, expressed or implied, and the NRC provides no endorsement for any evaluated product. The NRC accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained herein or the use of any evaluated product. The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.
Language