Product information

Product names

  • ATTICAT®
  • PROPINK®

Product description

The products are mineral fibre thermal insulation made from glass fibre and designed for pneumatic application using commercially available blowing equipment.

Manufacturing plants

This evaluation is limited to products produced at the following plants:

Product namesManufacturing plants
Edmonton, AB, CAScarborough, ON, CA
ATTICAT®Product evaluated by the CCMCProduct evaluated by the CCMC
PROPINK®Product evaluated by the CCMCProduct evaluated by the CCMC

Product evaluated by the CCMC Indicates that the product from this manufacturing facility has been evaluated by the CCMC

  Technical information

This evaluation is based on demonstrated conformance with the following criteria:

Evaluation requirements
Criteria number Criteria name
CAN/ULC-S702-14, Type 1Standard for Mineral Fibre Thermal Insulation For Buildings
CAN/ULC-S702.1:2014, Amendment 1, Type 5Standard for Mineral Fibre Thermal Insulation for Buildings, Part 1: Material Specification

The design thermal resistance values of the product at various design thicknesses are listed in the tables below.

Table 1. Design thermal resistance values - Owens Corning PROPINK® Fiberglas® Blown Insulation per CAN/ULC-S702-14 and CAN/ULC-S702.1-14-AMD1
Thermal resistanceTable footnote (1) Minimum installed thicknessTable footnote (2)Table footnote (3) Maximum coverage per bag Minimum number of bags Minimum mass per unit area
RSI R mm in. m2 ft.2 per 100 m2 per 1000 ft.2 kg/m2 lb./ft.2
2.1 12 114 4.5 16.60 178.7 6.0 5.6 0.90 0.19
2.8 16 151 6.0 12.45 134.0 8.0 7.5 1.20 0.25
3.5 20 189 7.4 9.96 107.2 10.0 9.3 1.51 0.31
4.2 24 227 8.9 8.30 89.3 12.0 11.2 1.81 0.37
4.9 28 265 10.4 7.11 76.6 14.1 13.1 2.11 0.43
5.6 32 302 11.9 6.21 66.9 16.1 14.9 2.41 0.49
6.3 36 337 13.3 5.45 58.7 18.3 17.0 2.75 0.56
7.0 40 372 14.6 4.85 52.2 20.6 19.1 3.09 0.63
7.7 44 407 16.0 4.37 47.0 22.9 21.3 3.43 0.70
8.4 48 442 17.4 3.97 42.8 25.2 23.4 3.78 0.77
8.75 50 458 18.0 3.81 41.1 26.2 24.4 3.93 0.81
9.1 52 477 18.8 3.64 39.2 27.5 25.5 4.12 0.84
9.8 56 511 20.1 3.37 36.2 29.7 27.6 4.45 0.91
10.5 60 546 21.5 3.13 33.6 32.0 29.7 4.80 0.98
11.2 64 581 22.9 2.92 31.4 34.3 31.9 5.15 1.05
11.9 68 615 24.2 2.74 29.5 36.5 34.0 5.48 1.12
12.25 70 632 24.9 2.65 28.6 37.7 35.0 5.65 1.16
12.6 72 650 25.6 2.57 27.7 38.9 36.1 5.83 1.19
13.3 76 684 26.9 2.43 26.2 41.1 38.2 6.17 1.26
14.1 80 724 28.5 2.29 24.6 43.8 40.7 6.56 1.34
Table 2. Design thermal resistance values - Owens Corning AttiCat™ blown-in insulation per CAN/ULC-S702-14 and CAN/ULC-S702.1-14-AMD1
Thermal resistanceTable footnote (1) Minimum installed thicknessTable footnote (2)Table footnote (3) Maximum coverage per bag Minimum number of bags Minimum mass per unit area
RSI R mm in. m2 ft.2 per 100 m2 per 1000 ft.2 kg/m2 lb./ft.2
2.1 12 114 4.5 15.05 162.0 6.6 6.2 0.90 0.19
2.8 16 151 6.0 11.29 121.5 8.9 8.2 1.20 0.25
3.5 20 189 7.4 9.03 97.2 11.1 10.3 1.51 0.31
4.2 24 227 8.9 7.53 81.0 13.3 12.3 1.81 0.37
4.9 28 265 10.4 6.45 69.4 15.5 14.4 2.11 0.43
5.6 32 302 11.9 5.63 60.7 17.7 16.5 2.41 0.49
6.3 36 337 13.3 4.94 53.2 20.2 18.8 2.75 0.56
7.0 40 372 14.6 4.40 47.4 22.7 21.1 3.09 0.63
7.7 44 407 16.0 3.96 42.6 25.2 23.4 3.43 0.70
8.4 48 442 17.4 3.60 38.8 27.8 25.8 3.78 0.77
8.75 50 458 18.0 3.46 37.2 28.9 26.9 3.93 0.81
9.1 52 477 18.8 3.30 35.5 30.3 28.1 4.12 0.84
9.8 56 511 20.1 3.05 32.9 32.8 30.4 4.45 0.91
10.5 60 546 21.5 2.83 30.5 35.3 32.8 4.80 0.98
11.2 64 581 22.9 2.64 28.5 37.8 35.1 5.15 1.05
11.9 68 615 24.2 2.48 26.7 40.3 37.4 5.48 1.12
12.25 70 632 24.9 2.41 25.9 41.5 38.6 5.65 1.16
12.6 72 650 25.6 2.33 25.1 42.9 39.8 5.83 1.19
13.3 76 684 26.9 2.21 23.7 45.3 42.1 6.17 1.26
14.1 80 724 28.5 2.07 22.3 48.3 44.8 6.56 1.34
Table 3. Application and installation requirements of the products per CAN/ULC-S702-09
Thermal resistance (m2·K/W-1)Table footnote (1) Minimum mass/unit area (kg/m2) Minimum installed thickness (mm)Table footnote (2)Table footnote (3) Maximum coverage per 13.6 kg bag (m2) Maximum coverage per 15 kg bag (m2)
2.10 0.90 112 15.1 16.7
2.80 1.20 150 11.4 12.5
3.50 1.50 187 9.1 10.0
4.20 1.80 225 7.6 8.3
4.90 2.10 262 6.5 7.2
5.60 2.40 299 5.7 6.3
6.30 2.70 337 5.0 5.6
7.00 2.99 374 4.5 5.0
7.70 3.29 412 4.1 4.6
8.40 3.59 449 3.8 4.2
8.75 3.74 468 3.6 4.0
9.10 3.89 487 3.5 3.9
9.80 4.19 524 3.2 3.6
10.50 4.49 561 3.0 3.3

 

Administrative information

Use of Canadian Construction Materials Centre (CCMC) assessments

This assessment must be read in the context of the entire CCMC Registry of Product Assessments, any applicable building code or by-law requirements, and/or any other regulatory requirements (for example, the Canada Consumer Product Safety Act, the Canadian Environmental Protection Act, etc.).

It is the responsibility of the user to confirm that the assessment they are using is current and has not been withdrawn or superseded by a later version on the CCMC Registry of Product Assessments.

Disclaimer

The National Research Council of Canada (NRC) has evaluated only the characteristics of the specific product described herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (such as authorities having jurisdiction, design professionals and specifiers). This evaluation is valid when the product is used as part of permitted construction, respecting all conditions and limitations stated in the evaluation, and in accordance with applicable building codes and by-laws.

This evaluation is provided without representation, warranty or guarantee of any kind, expressed or implied, and the NRC provides no endorsement for any evaluated product. The NRC accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained herein or the use of any evaluated product. The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.

Language

Une version française de ce document est disponible.
In the case of any discrepancy between the English and French version of this document, the English version shall prevail.

Copyright

© His Majesty the King in Right of Canada, as represented by the National Research Council of Canada, 2024

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the CCMC.

Page details

From: National Research Council Canada

Date modified: