Product information

Product names

  • Attic Protector Blowing Wool Insulation
  • Johns Manville Climate Pro

Product description

The products are a mineral-fibre building insulation made from glass fibre and designed for pneumatic application using commercially available blowing equipment.

Manufacturing plant

This evaluation is valid only for products produced at the following plant:

Product namesManufacturing plant
Innisfail, AB, CA
Attic Protector Blowing Wool InsulationProduct evaluated by the CCMC
Johns Manville Climate ProProduct evaluated by the CCMC

Product evaluated by the CCMC Indicates that the product from this manufacturing facility has been evaluated by the CCMC

  Technical information

This evaluation is based on demonstrated conformance with the following criteria:

Evaluation requirements
Criteria number Criteria name
CAN/ULC-S702.1:2014, Amendment 1, Type 5Standard for Mineral Fibre Thermal Insulation for Buildings, Part 1: Material Specification

The design thermal resistance value is 19.35 (m2 ·K)/W−1/m at a design density of 8.33 kg/m3.

The products must be installed in unconfined spaces with slopes not exceeding 4.5:12, and according to the following application charts:

Table 1. Coverage chart for Johns Manville Climate Pro
Thermal resistanceTable footnote (1) Minimum thicknessTable footnote (2)Table footnote (3) Minimum mass/area Maximum Coverage/Bag Minimum Bags/Area
RSI R mm in. kg/m2 psf m2 ft2 100 m2 1000 ft2
2.1 12 114 4.5 0.83 0.17 17.1 184.2 5.2 5.4
2.8 16 150 5.9 1.13 0.23 12.7 136.6 7.8 7.3
3.5 20 183 7.2 1.40 0.29 10.2 110.0 9.8 9.1
4.2 24 218 8.6 1.70 0.35 8.4 90.4 11.9 11.1
4.9 28 251 9.9 1.99 0.41 7.2 77.2 13.9 13.0
5.6 32 284 11.2 2.29 0.47 6.2 67.1 16.0 14.9
6.3 36 318 12.5 2.60 0.53 5.5 59.1 18.2 16.9
7.0 40 348 13.7 2.89 0.59 4.9 53.2 20.2 18.8
7.7 44 381 15.0 3.22 0.66 4.4 47.8 22.5 20.9
8.4 48 4.11 16.2 3.53 0.72 4.1 43.6 24.7 22.9
8.8 50 427 16.8 3.68 0.75 3.9 41.8 25.8 23.9
9.1 52 442 17.4 3.84 0.79 3.7 40.0 26.9 25.0
9.8 56 472 18.6 4.16 0.85 3.4 36.9 29.1 27.1
10.5 60 503 19.8 4.50 0.92 3.2 34.2 31.5 29.2
11.3 64 531 20.9 4.80 0.98 3.0 32.0 33.6 31.2
12.0 68 561 22.1 5.15 1.05 2.8 29.9 36.0 33.5
12.3 70 574 22.6 5.30 1.08 2.7 29.0 37.1 34.4
12.7 72 589 23.2 5.47 1.12 2.6 28.1 38.3 35.6
13.4 76 617 24.3 5.80 1.19 2.5 26.5 40.6 37.7
14.1 80 645 25.4 6.14 1.26 2.3 25.1 43.0 39.9

 

Table 2. Coverage chart for Attic Protector Blowing Wool Insulation
Thermal resistanceTable footnote (1) Minimum thicknessTable footnote (2)Table footnote (3) Minimum mass/area Maximum Coverage/Bag Minimum Bags/Area
RSI R mm in. kg/m2 psf m2 ft2 100 m2 1000 ft2
2.1 12 114 4.5 0.83 0.17 14.6 157.3 6.8 6.4
2.8 16 150 5.9 1.13 0.23 10.8 116.6 9.2 8.6
3.5 20 183 7.2 1.40 0.29 8.7 39.9 11.5 10.6
4.2 24 218 8.6 1.70 0.35 7.2 77.2 13.9 13.0
4.9 28 251 9.9 1.99 0.41 6.1 65.9 16.3 15.2
5.6 32 284 11.2 2.29 0.47 5.3 57.3 18.8 17.5
6.3 36 318 12.5 2.60 0.53 4.7 50.5 21.3 19.8
7.0 40 348 13.7 2.89 0.59 4.2 45.4 23.7 22.0
7.7 44 381 15.0 3.22 0.66 3.8 40.8 26.4 24.5
8.4 48 4.11 16.2 3.53 0.72 3.5 37.2 28.9 26.8
8.8 50 427 16.8 3.68 0.75 3.3 35.7 30.2 28.0
9.1 52 442 17.4 3.84 0.79 3.2 34.2 31.5 29.2
9.8 56 472 18.6 4.16 0.85 2.9 31.5 34.1 31.7
10.5 60 503 19.8 4.50 0.92 2.7 29.2 36.8 34.2
11.3 64 531 20.9 4.80 0.98 2.5 27.3 39.4 36.6
12.0 68 561 22.1 5.15 1.05 2.4 25.5 42.2 39.2
12.3 70 574 22.6 5.30 1.08 2.3 24.8 43.4 40.3
12.7 72 589 23.2 5.47 1.12 2.2 24.0 44.9 41.7
13.4 76 617 24.3 5.80 1.19 2.1 22.6 47.5 44.2
14.1 80 645 25.4 6.14 1.26 2.0 24.4 50.3 46.7

Administrative information

Use of Canadian Construction Materials Centre (CCMC) assessments

This assessment must be read in the context of the entire CCMC Registry of Product Assessments, any applicable building code or by-law requirements, and/or any other regulatory requirements (for example, the Canada Consumer Product Safety Act, the Canadian Environmental Protection Act, etc.).

It is the responsibility of the user to confirm that the assessment they are using is current and has not been withdrawn or superseded by a later version on the CCMC Registry of Product Assessments.

Disclaimer

The National Research Council of Canada (NRC) has evaluated only the characteristics of the specific product described herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (such as authorities having jurisdiction, design professionals and specifiers). This evaluation is valid when the product is used as part of permitted construction, respecting all conditions and limitations stated in the evaluation, and in accordance with applicable building codes and by-laws.

This evaluation is provided without representation, warranty or guarantee of any kind, expressed or implied, and the NRC provides no endorsement for any evaluated product. The NRC accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained herein or the use of any evaluated product. The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.

Language

Une version française de ce document est disponible.
In the case of any discrepancy between the English and French version of this document, the English version shall prevail.

Copyright

© His Majesty the King in Right of Canada, as represented by the National Research Council of Canada, 2023

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the CCMC.

Date modified: