Language selection

Search


[CCMC 11826-L] CCMC Standard compliance evaluation

In most jurisdictions this document is sufficient evidence for approval by Canadian authorities.

Learn more about CCMC recognition Look for the trusted CCMC mark on products to verify compliance.

Product information

Product names

  • LP®SmartSide®ExpertFinish®Lap
  • LP®SmartSide®ExpertFinish®Nickel Gap
  • LP®SmartSide®ExpertFinish®Panel
  • LP®SmartSide®ExpertFinish®Vertical Siding
  • LP®SmartSide®Lap
  • LP®SmartSide®Nickel Gap
  • LP®SmartSide®Panel
  • LP®SmartSide®Vertical Siding

Product description

The products are oriented strandboard (OSB) siding planks and panels with the face strands oriented in the machine (long panel) direction. The flakes are treated with zinc borate, and bonded with one of the following CCMC-evaluated isocyanate resins:

Table 1. Product characteristicsTable footnote footnote (1)
Product name Available finish Siding type Grade Length Width Thickness
LP®SmartSide®ExpertFinish®Lap Prefinished (or pre-painted - acrylic paint) Lap O-1 4 877 mm (16 ft.) 127 mm (5 in.)
152 mm (6 in.)
178 mm (7 in.)
203 mm (8 in.)
241 mm (9 1/2 in.)
305 mm (12 in.)

9.5 mm (3/8 in.)

LP®SmartSide®Lap Phenolic-resin-saturated primed overlay
LP®SmartSide®ExpertFinish®Lap Prefinished (or pre-painted - acrylic paint) Lap O-2 4 877 mm (16 ft.) 127 mm (5 in.)
152 mm (6 in.)
178 mm (7 in.)
203 mm (8 in.)
241 mm (9 1/2 in.)
305 mm (12 in.)

11.1 mm (7/16 in.)

LP®SmartSide®Lap Phenolic-resin-saturated primed overlay
LP®SmartSide®ExpertFinish®Nickel Gap Prefinished (or pre-painted - acrylic paint) Lap O-2 4 877 mm (16 ft.) 127 mm (5 in.)
152 mm (6 in.)
178 mm (7 in.)
203 mm (8 in.)
241 mm (9 1/2 in.)
305 mm (12 in.)
12.5 mm (1/2 in.)
LP®SmartSide®Nickel Gap Phenolic-resin-saturated primed overlay
LP®SmartSide®ExpertFinish®Panel Prefinished (or pre-painted - acrylic paint) Panel O-1 1 219 mm (4 ft.) to
5 486 mm (18 ft.)
1 219 mm (4 ft.) 9.5 mm (3/8 in.)
LP®SmartSide®Panel Phenolic-resin-saturated primed overlay
LP®SmartSide®ExpertFinish®Panel Prefinished (or pre-painted - acrylic paint) Panel O-2 1 219 mm (4 ft.) to
5 486 mm (18 ft.)
1 219 mm (4 ft.) 11.1 mm (7/16 in.)
15.1 mm (19/32 in.)
LP®SmartSide®Panel Phenolic-resin-saturated primed overlay
LP®SmartSide®ExpertFinish®Vertical Siding Prefinished (or pre-painted - acrylic paint) Vertical O-1 4 877 mm (16 ft.) 406 mm (16 in.) 9.5 mm (3/8 in.)
LP®SmartSide®Vertical Siding Phenolic-resin-saturated primed overlay
LP®SmartSide®ExpertFinish®Vertical Siding Prefinished (or pre-painted - acrylic paint) Vertical O-2 4 877 mm (16 ft.) 406 mm (16 in.) 11.1 mm (7/16 in.)
LP®SmartSide®Vertical Siding Phenolic-resin-saturated primed overlay

Manufacturing plants

This evaluation is limited to products produced at the following plants:

Product namesManufacturing plants
Dawson Creek, BC, CAHayward, WI, USHoulton (New Limerick), ME, USNewberry, MI, USSagola, MI, USSwan Valley (Minitonas), MB, CATomahawk, WI, USTwo Harbors, MN, US
LP®SmartSide®ExpertFinish®LapProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMC
LP®SmartSide®ExpertFinish®Nickel GapProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMC
LP®SmartSide®ExpertFinish®PanelProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMC
LP®SmartSide®ExpertFinish®Vertical SidingProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMC
LP®SmartSide®LapProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMC
LP®SmartSide®Nickel GapProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMC
LP®SmartSide®PanelProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMC
LP®SmartSide®Vertical SidingProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMCProduct evaluated by the CCMC

Product evaluated by the CCMC Indicates that the product from this manufacturing facility has been evaluated by the CCMC

  Technical information

This evaluation is based on demonstrated conformance with the following criteria:

Evaluation requirements
Criteria number Criteria name
CSA O437.0-93, Grade O1Standards on OSB and Waferboard
CSA O437.0-93, Grade O2Standards on OSB and Waferboard

Administrative information

Use of Canadian Construction Materials Centre (CCMC) assessments

This assessment must be read in the context of the entire CCMC Registry of Product Assessments, any applicable building code or by-law requirements, and/or any other regulatory requirements (for example, the Canada Consumer Product Safety Act, the Canadian Environmental Protection Act, etc.).

It is the responsibility of the user to confirm that the assessment they are using is current and has not been withdrawn or superseded by a later version on the CCMC Registry of Product Assessments.

Disclaimer

The National Research Council of Canada (NRC) has evaluated only the characteristics of the specific product described herein. The information and opinions in this evaluation are directed to those who have the appropriate degree of experience to use and apply its contents (such as authorities having jurisdiction, design professionals and specifiers). This evaluation is valid when the product is used as part of permitted construction, respecting all conditions and limitations stated in the evaluation, and in accordance with applicable building codes and by-laws.

This evaluation is provided without representation, warranty or guarantee of any kind, expressed or implied, and the NRC provides no endorsement for any evaluated product. The NRC accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained herein or the use of any evaluated product. The NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.

Language

Une version française de ce document est disponible.
In the case of any discrepancy between the English and French version of this document, the English version shall prevail.

Copyright

© His Majesty the King in Right of Canada, as represented by the National Research Council of Canada, 2024

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the CCMC.

Page details

From: National Research Council Canada

Date modified: